| Analysis
Of Sound Cards
| CUSTOMER:
CHIP
Magazine Test Center
GOAL
Comparison
of the output quality and (dip) noises of the sound cards in the
market.
DESIGN
AND TECHNOLOGY:
A
multi-functional data acqusition card was used to measure the
signals on the analog output of the sound card and to generate
a signal with a known frequency and (genlik). LabVIEW 6i was used
for the test software platform. Both of these are the products
of National Instruments company.
|
|
SOLUTION:
To
measure the noise caused by the inner electronics of the sound cards
the sound volume was at the maximum and level of the (dip) noises on
the analog output were measured. Another criteria of the sound card
test , the measurement of the disortion of the signals was made by sending
a known signal with a known frequency and (genlik) and analysing the
same signal's output.
RESULT:
The
similar tests which were made in CHIP Germany before, can be made in
CHIP Turkey from now on.
|