Number input channels |
Four (4) differential inputs standard, 12 optional |
Input amplifier |
Instrumentation amp, 110 dB CMRR, hardware programmable gain from 1 to 1000 |
Bridge excitation |
3 VDC, regulated to 0.1%, up to 10 milliamps at 3 VDC available for 10 millisecond duration pulsed bridge excitation |
Sensor types |
Piezoresistive bonded foil & semiconductor strain gauges, pressure/load/torque transducers, thermocouples |
A/D converter |
12 bit resolution successive approx. type (standard)
24 bit resolution, sigma delta type (optional)
A/D conversion synchronous with pulsed bridge excitation |
Identification (ID) |
Factory programmable, 16 bits |
Update rates |
20 Hz/channel w/ 44 kHz operating freq., 12 bit A/D
1 Hz/channel w/ 44 kHz operating freq., 24 bit A/D
200 Hz/channel w/ 125 kHz operating freq., 12 bit A/D |
Communication method |
Switched reactance, pulse code modulated serial (RS-232), clocked synchronous |
Coil-to-coil separation |
Coil geometry dependent, ~20 mm w/ matched 50 mm diameter coils |
EmbedSense power |
200 microamperes at 3 VDC, not including bridge excitation, obtained by rectification of external AC magnetic field |
Operating temperatures |
-40 to +150 degrees Celsius |
Operating G levels |
Independently tested to 50,000 G's |